gEDA-bug: [ geda-Bugs-1692431 ] Gattrib can't handle multiple net= attributes



Bugs item #1692431, was opened at 2007-04-01 10:23
Message generated for change (Tracker Item Submitted) made by Item Submitter
You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=818426&aid=1692431&group_id=161080

Please note that this message will contain a full copy of the comment thread,
including the initial issue submission, for this request,
not just the latest update.
Category: gattrib
Group: None
Status: Open
Resolution: None
Priority: 5
Private: No
Submitted By: Stephen Williams (stevewilliams)
Assigned to: Nobody/Anonymous (nobody)
Summary: Gattrib can't handle multiple net= attributes

Initial Comment:
I have a schematic that attaches to a component
multiple net= attributes in order to bind GND,
Vcc3, Vccaux, Vccint, etc. gschem and gnetlist
handle this fine, but gattrib will overwrite the
net= attributes in a way that causes values to
be replaced with duplicates of other net= instances
on the same component.

To reproduce, place a component, then attach
multiple net= attributes to connect multiple
to multiple nets:  i.e.

net=Vcc3:1,3,5
net=GND:2,4,6
net=Vccaux:8,9

Then go into gattrib, edit some other attribute,
and write the schematic back out. Likely the net=
attributes will be corrupted.


----------------------------------------------------------------------

You can respond by visiting: 
https://sourceforge.net/tracker/?func=detail&atid=818426&aid=1692431&group_id=161080


_______________________________________________
geda-bug mailing list
geda-bug@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-bug