[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-bug: [Bug 700189] gschem: invalid dialog text when closing unsaved schematic
status fixcommitted
done
commit 355fd9bae3392c120d85f81feff04cae5a0ed42e
Author: Krzysztof Kosciuszkiewicz <k.kosciuszkiewicz@xxxxxxxxx>
Date: Sat Jan 8 02:46:28 2011 +0100
gschem: fix secondary label in close confirmation dialog
Secondary label used a pointer string that was previously freed. This
bug was introduced in commit d8803215ea59.
Reviewed-by: Peter TB Brett <peter@xxxxxxxxxxxxx>
Closes-bug: lp-700189
--
You received this bug notification because you are a member of gEDA Bug
Team, which is subscribed to gEDA.
https://bugs.launchpad.net/bugs/700189
Title:
gschem: invalid dialog text when closing unsaved schematic
Status in GPL Electronic Design Automation tools:
Fix Committed
Bug description:
When closing a window with a single page unsaved schematic, a dialog box with partially garbled text appears.
It looks like a memory management issue.
_______________________________________________
geda-bug mailing list
geda-bug@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-bug