[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

gEDA-bug: [Bug 787637] Re: auto-uref is broken



Thanks. No autonumber works as expected on add-component. It does not
work on copy. No matter how I copy, the refdes stays the same on paste
(yp, [ctrl-c], edit menu). I can't get Peters script to work, either.
Feels like the copy-copy-component-hook just does nothing.

This are the gschemrc lines by which I try to activate renumber on copy:

(load-from-path "auto-uref.scm")
(load-from-path "unnumber-refdes.scm")
;(add-hook! copy-component-hook unnumber-refdes)
(add-hook! new-page-hook auto-uref-init-page)
(add-hook! add-component-hook auto-uref)
(add-hook! copy-component-hook auto-uref)

---<)kaimartin(>---

-- 
You received this bug notification because you are a member of gEDA Bug
Team, which is subscribed to gEDA.
https://bugs.launchpad.net/bugs/787637

Title:
  auto-uref is broken

Status in GPL Electronic Design Automation tools:
  Fix Committed

Bug description:
  The auto-uref.scm script does not work as expected. It uses even
  numbers only and produces duplicate refdeses.

  To reproduce:

  0) add these lines in gschemrc to activate auto-uref:
  ÂÂÂ(load-from-path "auto-uref.scm")
  ÂÂÂ(add-hook! add-component-hook auto-uref)
  ÂÂÂ(add-hook! copy-component-hook auto-uref)

  1) open gschem.

  2) Open the symbol chooser dialog and add three symbols resistor-2.sym
  from the Basic_devices library.

  Refdeses should be R1, R2, R3, but will be R2, R4, R6.

  3) save the sheet with save-as.

  4) close gschem.

  5) open  gschem with the saved sheet.

  6) Add some more resistor-1.sym via the chooser dialog.

  Refdeses will again be R2, R4, R6, etc. That is, duplicates to the
  symbols already present on the sheet.

  ---<)kaimartin(>---


_______________________________________________
geda-bug mailing list
geda-bug@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-bug