Re: gEDA-user: rat not connected, can't find it
On Thu, Apr 10, 2008 at 2:22 AM, Traylor Roger
<traylor@xxxxxxxxxxxxxxxxxxxx> wrote:
> Guys,
> When I optimize the rats, the log says I have one unconnected
> rat. I cannot find it for the life of me. Tried turning off
> all layers but rats but can't any rats there either.
>
> Looked over the documents and can't find a way to determine
> what net corresponds to an unconnected rat. Any ideas?
What I usually do is turn off all layers, the grid, the silk, pads and vias.
I use a black background and light color traces. The unconnected
next is usually very easy to spot.
Most of the the unconnected nets I have found were the result
of a trace that is over a pad on the opposite side of the board.
(* jcl *)
--