Hi,
FWIW, I have (sequential) pin numbers in both symbols and footprints {1 ...
N}.
Pin (pad) names (in footprints) are in the range {1A ... 10K} for a 100 pad
BGA (as in a 10 rows by 10 columns package).
Pin labels (in symbols) should have a meaningfull value in the schematic.
My EUR 0.02.
Kind regards,
Bert Timmerman.
-----Oorspronkelijk bericht-----
Van: geda-user-bounces@xxxxxxxxxxxxxx
[mailto:geda-user-bounces@xxxxxxxxxxxxxx] Namens David Kuehling
Verzonden: zondag 31 augustus 2008 14:47
Aan: geda-user@xxxxxxxxxxxxxx
Onderwerp: gEDA-user: Centroid data and BGA footprints
Hi,
I'm just wondering, how do I get sensible rotation information in the
centroid data for footprints that don't have a pin numbered '1', but only a
pin numbered '1B'. In my case that's a BGA footprint, where I chose pin
numbers 1B..7E in accordance to the part's data sheet.
Do I have to rename the pins (and update the symbol), or can I add a kind of
rotation hint, or a pseudo-pin #1 to my m4 footprint?
Thanks for any hints,
cheers,
David
--