[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: DRC2 Problem (gEDA-2005080313)
Hi Holger,
this bug should be fixed in the geda tarball released this week. Try
upgrading to the latest release, and let me know if you get the same
error.
Regards,
Carlos
El mar, 24-01-2006 a las 00:19 +0100, Holger Oehm escribiÃ:
> Hi Carlos, Hi Neal,
>
> I just stumbled across the same problem (I simply tried to
> run "gnetlist -v -g drc2 one.sch two.sch" with the
> schematics described in the gschem-> gsch2pcb -> PCB tutorial)
> and gnetlists answer ended with:
> ...
> ERROR: In procedure apply:
> ERROR: Wrong type argument in position 1: #<variable 8059f10 binding: #<primitive-procedure <>>
>
> Do you happen to know, whether this problem has been solved in the meantime?
>
> Best regards,
> Holger.
>
> On Mon, 09 May 2005 20:02:36, Carlos Nieves Ãnega wrote:
> > Hi Neal,
> > the call to scm_sort_list_x "only" sorts the list returned by the
> > function g_get_slots, which is used by the backends to get the slots
> > used in a package. For example: if you use slots 1 and 3 of U1 in your
> > schematic, g_get_slots will always return a list (1, 3) after calling
> > scm_sort_list_x. Commenting out that call, g_get_slots may return (3,
> > 1), so it will only affect to the backends relying on a sorted list.
> > IIRC, it shouldn't affect any report made by the drc2 backend. I think
> > others backends are not affected, but I can't tell it for sure. Just try
> > it.
> >
> > Regards,
> >
> > Carlos
> >
> > El lun, 09-05-2005 a las 12:32 -0500, Neal Baer escribiÃ:
> >> Carlos,
> >> Thanks for your response.
> >> Do know, by commenting out the "scm_sort_list_x" call in function "g_get_slots",
> >>
> >> * Will this affect "gnetlist -g drc2" report generation ?
> >> * Will this affect "gnetlist -g PCB" netlist generation?
> >>
> >> Thanks,
> >>
> >> Neal
> >>
> >> Carlos Nieves Ãnega wrote:
> >>
> > >Hi Neal,
> > >this is not a drc2 bug, but a gnetlist one. I found where the problem
> > >is, but I'm not a scheme guru, so I don't understand yet what is
> > >happening.
> > >The problem is in g_get_slots function, in g_netlist.c. There is a call
> > >to scm_sort_list_x just before the function's end. This is where this
> > >error is generated. I tried to just commenting out the call to
> > >scm_sort_list_x, and gnetlist worked well.
> > >The list passed to scm_sort_list_x is (1, 1).
> > >
> > >Anyone knows what's the problem here?
> > >
> > >Thanks,
> > >
> > >Carlos
> > >
> > >El sÃb, 07-05-2005 a las 23:05 -0500, Neal Baer escribiÃ:
> > >
> > >
> > >>I just compiled gEDA-2005080313, SuSE 9.2 yesterday.
> > >>
> > >>I found what seems to be a bug with gnet-drc2.scm. Creating a simple
> > >>schematic of 2 resistors, having the same reference (i.e. R1), same or
> > >>different values, causes the DRC2 output as shown below.
> > >>
> > >>I found the problem with a slotted part, thus each slot instance has the
> > >>same reference designator. This stops the DRC2 testing to complete,
> > >>which deems it useless in this scenario. I had to ensure that the
> > >>reference numbers differ for the slotted parts to get DRC2 to complete
> > >>its test.
> > >>
> > >>Creating a netlist with the same reference numbers for slotted parts
> > >>worked properly.
> > >>
> > >>Any suggestions or workarounds?
> > >>
> > >>Thanks,
> > >>
> > >>Neal
> > >>
> > >>DRC OUTPUT OF TEST SCHEMATIC WITH DUPLICATE REFERENCES
> > >>
> > >>
> > >>
> > >>>nbaer@linux:~/Projects/Terrigena/FILTER-DESIGN/FRONT-END-FILTER>
> > >>>gnetlist -g drc2 test.sch -o -
> > >>>gEDA/gnetlist version 20050313
> > >>>gEDA/gnetlist comes with ABSOLUTELY NO WARRANTY; see COPYING for more
> > >>>details.
> > >>>This is free software, and you are welcome to redistribute it under
> > >>>certain
> > >>>conditions; please see the COPYING file for more details.
> > >>>
> > >>>Remember to check that your schematic has no errors using the drc2
> > >>>backend.
> > >>>You can do it running 'gnetlist -g drc2 your_schematic.sch -o
> > >>>drc_output.txt'
> > >>>and seeing the contents of the file drc_output.txt.
> > >>>
> > >>>Loading schematic
> > >>>[/home/nbaer/Projects/Terrigena/FILTER-DESIGN/FRONT-END-FILTER/test.sch]
> > >>>Checking non-numbered parts...
> > >>>
> > >>>Checking duplicated references...
> > >>>ERROR: Duplicated reference R1.
> > >>>
> > >>>Checking nets with only one connection...
> > >>>ERROR: Net has only one connected pin: dgnd
> > >>>ERROR: Net has only one connected pin: unnamed_net1
> > >>>
> > >>>Checking type of pins connected to a net...
> > >>>
> > >>>Checking unconnected pins...
> > >>>
> > >>>Checking slots...
> > >>>
> > >>>Checking duplicated slots...
> > >>>ERROR: In procedure apply:
> > >>>ERROR: Wrong type argument in position 1: #<variable 80661b8 binding:
> > >>>#<primitive-procedure <>>
> > >>>nbaer@linux:~/Projects/Terrigena/FILTER-DESIGN/FRONT-END-FILTER>
>