Re: gEDA-user: nets in symbols



On Tue, 2007-03-06 at 09:58 +0000, Seb James wrote:
> On Mon, 2007-03-05 at 10:41 -0700, Marc Moreau wrote:
> > On Mon, 05 Mar 2007 14:51:45 +0000
> > Seb James <seb@xxxxxxxxxxxx> wrote:
> > 
> > > ERROR: Duplicated reference U3501.
> > 
> > I neglected to say one important thing about multiple parts...
> > Each unit must have a unique refdes, but all the same.  Okay..  Example...
> > 
> > I call my parts
> > U3163pwr
> > U3163ioone
> > U3163iotwo
> > U3163adc
> 
> Great! That's it!

Ah, no, that's not it quite yet...

I called my slotted parts U3501io and the power part U3501pwr.

That means I have 4 U3501io symbols in my schematic and 1 U3501pwr.

On the pcb layout, I get 2 footprints - one for U3501pwr and one for
U3501io...

I tried a step further, and called the io symbols:

U3501ioone
U3501iotwo
U3501iothree
U3501iofour

And then I get 5 footprints on the diagram...

Have I missed anything?

Seb