On Wed, Mar 21, 2007 at 04:00:28PM -0400, Ryan Seal wrote:It worked. I changed my layer names via emacs and then swapped my component-side and solder-side labels in pcb. I suppose I could have done this through the pcb interface (as DJ Delorie suggested) but wasn't quite sure and I laid down almost 500 traces before catching my obvious mistake - so I was a little hesitant.
problem and need to move each trace to the opposite side of the board.
I did this once. It's easy, just edit the .pcb in a text editor, find the block with the lines, and move them around. So you'll see something like:
Layer(4 "component") ( Line[239000 53000 230900 53000 2500 2000 ""] Line[259000 38000 254000 43000 2500 2000 ""] ... )
Just move the Line bits (or change the Layer "statement").
Thanks again, Ryan
_______________________________________________ geda-user mailing list geda-user@xxxxxxxxxxxxxx http://www.seul.org/cgi-bin/mailman/listinfo/geda-user