Re: gEDA-user: newbie gschem problem
Hi Will,
On Freitag, 21. März 2008, Willem Granjé wrote:
> I have started working with this tutorial:
> http://www.geda.seul.org/docs/current/tutorials/gsch2pcb/tutorial.htm
>l
>
> All goes well until the BNC connector: I can't connect to the
> terminals...
>
> how do I get the terminals on the grid?
>
> or how can I connect without using the snap?
Remove the symbol and readd it while snap to the grid is enabled.
There are some possible reasons why the symbol is not on grid:
* you've added or moved the symbol without grid enabled
* you're using gEDA version between 20070216 and 1.2.0
which has a Edit->Mirror bug
Regards
Werner