Old description:
> I think the operator should see, at info level:
> - see one line when it fails (with the nick/fp of both relays and the
> reason)
> - see one line when it doesn't (with the nick/fp of both relays)
> Currently the failures are logged at several po
> ints in the code (and several levels)
> and the messages don't provide the same available information
>
> For instance, every time a relay fails to be measured, all these lines
> are shown:
> 2018-12-05 12:35:12,104 WARNING Thread-5 circuitbuilder.py:83 -
> _build_circuit_impl - Circuit failed to be created: CHANNEL_CLOSED
> 2018-12-05 12:35:12,107 WARNING Thread-5 circuitbuilder.py:83 -
> _build_circuit_impl - EXTENDCIRCUIT returned unexpected response code:
> 551
> 2018-12-05 12:35:12,108 WARNING Thread-5 circuitbuilder.py:83 -
> _build_circuit_impl - EXTENDCIRCUIT returned unexpected response code:
> 551
> 2018-12-05 12:35:12,109 WARNING Thread-5 scanner.py:203 - measure_relay -
> Could not build circuit involving UbuntuCore250
> 2018-12-05 12:36:13,848 WARNING Thread-5 scanner.py:217 - measure_relay -
> When measuring default 565B07B9 the destination seemed to have stopped )
>
> I think this should be only 1 line a level INFO, and the rest at DEBUG
> level
>
> For success measurements, it logs
> 2018-12-05 12:40:13,947 INFO Thread-1 resultdump.py:544 - handle_result -
> Torrr 96EA4E2C finished measurement with ResultSuccess
>
> Instead of ResultSuccess, should say which two relays were measureed.
New description:
I think the operator should see, at info level:
- see one line when it fails (with the nick/fp of both relays and the
reason)
- see one line when it doesn't (with the nick/fp of both relays)
Currently the failures are logged at several po
ints in the code (and several levels)
and the messages don't provide the same available information
For instance, every time a relay fails to be measured, all these lines are
shown:
{{{
2018-12-05 12:35:12,104 WARNING Thread-5 circuitbuilder.py:83 -
_build_circuit_impl - Circuit failed to be created: CHANNEL_CLOSED
2018-12-05 12:35:12,107 WARNING Thread-5 circuitbuilder.py:83 -
_build_circuit_impl - EXTENDCIRCUIT returned unexpected response code: 551
2018-12-05 12:35:12,108 WARNING Thread-5 circuitbuilder.py:83 -
_build_circuit_impl - EXTENDCIRCUIT returned unexpected response code: 551
2018-12-05 12:35:12,109 WARNING Thread-5 scanner.py:203 - measure_relay -
Could not build circuit involving UbuntuCore250
2018-12-05 12:36:13,848 WARNING Thread-5 scanner.py:217 - measure_relay -
When measuring default 565B07B9 the destination seemed to have stopped )
}}}
I think this should be only 1 line a level INFO, and the rest at DEBUG
level
For success measurements, it logs
{{{
2018-12-05 12:40:13,947 INFO Thread-1 resultdump.py:544 - handle_result -
Torrr 96EA4E2C finished measurement with ResultSuccess
}}}
Instead of ResultSuccess, should say which two relays were measured.
Edit: format
--
Comment (by juga):
Replying to [ticket:28736 juga]:
> I think the operator should see, at info level:
> - see one line when it fails (with the nick/fp of both relays and the
reason)
> - see one line when it doesn't (with the nick/fp of both relays)
> Currently the failures are logged at several po
> ints in the code (and several levels)
> and the messages don't provide the same available information
>
> For instance, every time a relay fails to be measured, all these lines
are shown:
> 2018-12-05 12:35:12,104 WARNING Thread-5 circuitbuilder.py:83 -
_build_circuit_impl - Circuit failed to be created: CHANNEL_CLOSED
> 2018-12-05 12:35:12,107 WARNING Thread-5 circuitbuilder.py:83 -
_build_circuit_impl - EXTENDCIRCUIT returned unexpected response code: 551
> 2018-12-05 12:35:12,108 WARNING Thread-5 circuitbuilder.py:83 -
_build_circuit_impl - EXTENDCIRCUIT returned unexpected response code: 551
> 2018-12-05 12:35:12,109 WARNING Thread-5 scanner.py:203 - measure_relay
- Could not build circuit involving UbuntuCore250
> 2018-12-05 12:36:13,848 WARNING Thread-5 scanner.py:217 - measure_relay
- When measuring default 565B07B9 the destination seemed to have stopped )
>
> I think this should be only 1 line a level INFO, and the rest at DEBUG
level
>
> For success measurements, it logs
> 2018-12-05 12:40:13,947 INFO Thread-1 resultdump.py:544 - handle_result
- Torrr 96EA4E2C finished measurement with ResultSuccess
>
> Instead of ResultSuccess, should say which two relays were measureed.
--