[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: [tor-relays] Lost HSDir flag




On 8 Apr 2018, at 16:25, tschador@xxxxxxxxx wrote:

Hi,

every time Tor is restarted (for example after upgrading) the HSDir flag
of my relay (6A7551EEE18F78A9813096E82BF84F740D32B911) is lost for 4
days. Why?

The minimum uptime for HSDirs is 96 hours (4 days):
https://gitweb.torproject.org/torspec.git/tree/dir-spec.txt#n2524

Why 4 days?

HSDirs rotate every 24 hours. If a relay has been up for 4 days, then it is
likely to be up for the next 24 hours. So it is given the flag.

(If a HSDir goes down, it takes a few hours for clients and services to find
out it is down. If too many HSDirs go down at the same time, the services
assigned to those HSDirs are unreachable for a few hours. The minimum
uptime reduces the risk of HSDir downtime.)

T
_______________________________________________
tor-relays mailing list
tor-relays@xxxxxxxxxxxxxxxxxxxx
https://lists.torproject.org/cgi-bin/mailman/listinfo/tor-relays