[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: init.d script for multi instance TOR servers



Hi,

On 08.09.2010 14:34, Karsten Loesing wrote:
>> If I enable CellStatistics, I get a lot of warnings printed to the log:
>> [warn] connection_or_flush_from_first_active_circuit(): Bug: Cannot
>> determine insertion time of cell.
> Interesting! Did you restart Tor with that config option or did you
> edit the torrc and HUP it? I guess the latter.

Yes. When I restart the nodes, the warning goes away.

What I haven't seen before is this:

[notice] Based on 368 circuit times, it looks like we don't need to wait
so long for circuits to finish. We will now assume a circuit is too slow
to use after waiting 10 seconds.
[notice] Based on 369 circuit times, it looks like we need to wait
longer for circuits to finish. We will now assume a circuit is too slow
to use after waiting 11 seconds.
[notice] Based on 371 circuit times, it looks like we don't need to wait
so long for circuits to finish. We will now assume a circuit is too slow
to use after waiting 10 seconds.

Moritz