[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [f-cpu] Register Bank



On Fri, 3 Aug 2001, Ben Franchuk wrote:

> Juergen Goeritz wrote:
> > Depends on how long you can wait after reset. Some registers,
> > e.g. of the internal pipeline statemachines have to be reset
> > anyway. If you use 256 registers in some inplementation you
> > would wait 256 clocks before the built-in selftest r
> outines
> > can start or you make the reset a part of these. :-)
> Reset pulse is over kill often on length like 1/100 of second. 
> You may want to have two resets -- hard reset like power on.
> and warm reset like ctl Alt Del.

There is no warm reset in hardware! That's just software type.

JG

*************************************************************
To unsubscribe, send an e-mail to majordomo@seul.org with