Hi, I just tested the patch series and I have a little problem with it.
It removes the red cues even form unnamed nets. So when I create a net with 2 components and than
make another line from it ending nowhere it has no cues.
I think it would be better to remove the cue just from "named nets with
at least 2 different nets with the same name".
--
You received this bug notification because you are a member of gEDA Bug
Team, which is subscribed to gEDA.
https://bugs.launchpad.net/bugs/707064
Title:
Remove unconnected net cues for netname connected nets
Status in GPL Electronic Design Automation tools:
New
Bug description:
This came up after a presentation with potential users.
The red cues on the end of unconnected net was perceeved as a nice
warning that something was unconnected.
Their expectation was that a net connected at one end should lose the
second cue (on its unconnected end) if the net is named. This could be
implemented either to mean "has a netname=" attribute, or that it is
connected to something which has one.
This helps to preserve the semantic that "red splodge" == something to
fix.
We also noted that the pin cues were not nearly as visible as they
ought to be when projected!