[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
gEDA-user: A couple o' questions
- To: geda-user@xxxxxxxx
- Subject: gEDA-user: A couple o' questions
- From: David Logan <djlogan2@xxxxxxxxxxx>
- Date: Wed, 05 Apr 2006 08:54:05 -0600
- Delivered-to: archiver@seul.org
- Delivered-to: geda-user-outgoing@seul.org
- Delivered-to: geda-user@seul.org
- Delivery-date: Wed, 05 Apr 2006 10:54:35 -0400
- Reply-to: geda-user@xxxxxxxx
- Sender: owner-geda-user@xxxxxxxx
- User-agent: Mozilla/5.0 (X11; U; Linux i686; en-US; rv:1.7b) Gecko/20040316
1) Is there a reason that
gnetlist -g drc2
does not report invalid slots?
If you take a couple of 7400 logic gates, and make one slot=1 and
another slot=6, -g drc2 reports slot#2 as unused, but does not report
slot#6 as invalid. I'm not sure what gsch2pcb would do with it after
that, or what gnetlist would do when building a net. I think gnetlist
treats slot=6 as slot=1 for purposes of pin assignment.
2) I'm sorry, but (as usual), I can't find anything to answer my
question in the wiki. It's surely not a fault of the information in the
wiki, I have the exact same problem in every wiki I try to search. But
what I'm looking for is: I *know* I saw somewhere recently text on how
to set pins as "not connected" for purposes of drc checking. But I'll be
damned if I can find it now. In the wiki, I tried: not connected, nc,
drc not connected, drc nc, how to set pins not connected, and probably
some others, nothing useful came back.
So how is that done again? Sorry.
David Logan