[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: PCB connections
On Wed, Apr 23, 2008 at 11:09 PM, Ian Chapman <ichapman@xxxxxxxxxxxx> wrote:
> Hi, I thought that I was able to connect my layout footprints without
> problems. What I am finding is that with some of the smaller smt parts
> that I am not able to get the trace close to the pad. I started with
> TQFP100_14.fp that I pulled into my footprints from the distribution.
> It has pads defined the old way "Pad(-75 39 -25 39 11 "1" 0x00)" without
> a clearance and mask defined. I updated it to the new format "Pad[-7500
> 5800 -2500 5800 1100 300 1200 "" "2" "square"]" and still have the
> situation that I'm not able to terminate the trace on the pad. Even
> using the Skinny lines width 5.0 and spacing 5.0 I'm not able to connect
> to the pad. It is fine with 0603 and soic8 parts. All suggestions will
> be gratefully accepted. Regards Ian.
* Try turning of the pads and see if there is a small amount amount of copper
under the pad.
* Are your traces and pads on the same side of the board?
* Can you connect with with "auto enforce DRC clearance" off?
(* jcl *)
--
http://www.luciani.org
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user