[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
gEDA-user: PCB connections
Hi, I thought that I was able to connect my layout footprints without
problems. What I am finding is that with some of the smaller smt parts
that I am not able to get the trace close to the pad. I started with
TQFP100_14.fp that I pulled into my footprints from the distribution.
It has pads defined the old way "Pad(-75 39 -25 39 11 "1" 0x00)" without
a clearance and mask defined. I updated it to the new format "Pad[-7500
5800 -2500 5800 1100 300 1200 "" "2" "square"]" and still have the
situation that I'm not able to terminate the trace on the pad. Even
using the Skinny lines width 5.0 and spacing 5.0 I'm not able to connect
to the pad. It is fine with 0603 and soic8 parts. All suggestions will
be gratefully accepted. Regards Ian.