[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: hierarchy and net attributes.
On Apr 8, 2010, at 2:28 PM, Dave N6NZ wrote:
> So as I understand the current situation in gschem/gnetlist, there is no way to get a global net in a hierarchical design other than to set:
>
> (hierarchy-netattrib-mangle "disabled")
>
> in gnetlistrc. However, now all net attributes will become global nets. So, if one uses off-page connector symbols, the net attribute in off-page connectors will now become a global net. So, in essence, there is no way to have a multi-sheet lower level schematic that accesses global nets using the "disable mangle" hack. Disabling mangling has the side effect of turning any signal in a lower level sheet with an off-page reference into a global net.
>
> Is this correct? Or am I missing something?
I see that I was missing that hierarchy-netattrib-mangle and hierarchy-netname-mangle are two different things.
>
> -dave
>
>
>
>
> _______________________________________________
> geda-user mailing list
> geda-user@xxxxxxxxxxxxxx
> http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
>
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user