[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: gattrib not showing part_numbers
It seems like gnetlist could be used to "promote" an attribute to the
schematic. Does anyone know if someone has tried that?
Oliver
__________________________________________________________________
From: Stuart Brorson <sdb@xxxxxxxxxx>
To: gEDA user mailing list <geda-user@xxxxxxxxxxxxxx>
Sent: Wed, February 9, 2011 4:12:18 AM
Subject: Re: gEDA-user: gattrib not showing part_numbers
IIRC, gattrib will handle attributes embedded in the schematic, not
the symbol. The reason is that gattrb cannot reach into a symbol and
modify its attributes. It only edits attributs in the schematic.
Therefore, this is a feature.
Stuart
On Tue, 8 Feb 2011, Oliver King-Smith wrote:
> I have defined a number of symbols with an embedded part # for ease
of
> ordering. An example of such a part # is
>
> T 700 1000 8 10 0 0 0 0 1
> part_number=PMBS3904
>
> This is visible on the schematic (if you turn on invisible text).
However when
> I run gattrib on the schematic with this in it, I don't see the part
number show
> up. I do see my part numbers show up for items where I entered it as
an
> attribute for the particular part (such as a capacitor).
>
> Does anyone know if this is a feature or bug?
>
> Oliver
>
>
>
>
_______________________________________________
geda-user mailing list
[1]geda-user@xxxxxxxxxxxxxx
[2]http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
References
1. mailto:geda-user@xxxxxxxxxxxxxx
2. http://www.seul.org/cgi-bin/mailman/listinfo/geda-user
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx