> Note the ring terminals are long-barrel, brazed-seam, non-insulated. By
> long barrel you have longer crimp region, stronger, lower resistance.
> Long means about 5 to 7 times the diameter of the wire.
> There is a seam/joint in the barrel. You want welded/brazed seam.
> Avoid ones with open crack in barrel.
> The non-insulated ring terminals are to be preferred, because you can
> perform a better, more agressive type crimp. This is kind of like the
> difference between biting with teeth, and biting with no teeth.
>
>
>