[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: [PATCH 1/2] gnetlist: Add access to all	attributes	from components	with multiple symbol instances.
On Jan 4, 2011, at 3:45 PM, Kai-Martin Knaak wrote:
> Patrick Bernaud wrote:
> 
>>> However, a less severe wart remains: In case of multiple values for the
>>> same attribute, the output still depends on the order the symbols were
>>> added to the schematics.
>> 
>> This behaviour is intentional. 
> 
> What is the intention? I mean, should the order objects were entered in 
> gschem be allowed to make a difference whatsoever?
Good question.
I'm sure that those who mistakenly believe that disputes here are personal will be shocked that we agree ;-)
> 
> 
>> But you can change it locally.
> 
> Local to where? In my gafrc? In a gnetlist back-end?
In a gnetlist plug-in loaded with the -m flag, or in a gnetlist back end.
---
John Doty              Noqsi Aerospace, Ltd.
This message contains technical discussion involving difficult issues. No personal disrespect or malice is intended. If you perceive such, your perception is simply wrong. I'm a busy person, and in my business "go along to get along" causes mission failures and sometimes kills people, so I tend to be a bit blunt.
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user