Re: gEDA-user: 0805 geometry, was: Script for converting mm to hundredths of thou
On Tue, 2010-07-27 at 23:30 +0200, Armin Faltl wrote:
>
> One thing I'd like to know is the exact meaning of "clearance"
>From http://www.ssalewski.de/PcbFootprintRef.txt
>Clearance defines the separation of the pad to any surrounding copper.
>There is a factor of two involved: separation = clearance/2
> in a pad - does this get added to thicknes or is it measured from
> the center line of the pad, same with mask.
>
>
> Below is what I think a comprimise reflow/hand-solder landpattern
> for a smd-0805 should really look like, as opposed to the library;
> the very reason I started my own 0805:
>
Is sfg.rb not working fine for you?
http://www.ssalewski.de/SFG.html.en
OK, if you do not like Ruby language, you may try footgen.py, or DJ's
online tool:
http://www.gedasymbols.org/user/dj_delorie/tools/2pad.html
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user