Re: gEDA-user: DRC2 Problem (gEDA-2005080313)



Carlos,
Thanks for your response. Do know, by commenting out the "scm_sort_list_x" call in function "g_get_slots",
* Will this affect "gnetlist -g drc2" report generation ?


   * Will this affect "gnetlist -g PCB"  netlist generation?

Thanks,

Neal

Carlos Nieves Ónega wrote:

Hi Neal,
this is not a drc2 bug, but a gnetlist one. I found where the problem
is, but I'm not a scheme guru, so I don't understand yet what is
happening.
The problem is in g_get_slots function, in g_netlist.c. There is a call
to scm_sort_list_x just before the function's end. This is where this
error is generated. I tried to just commenting out the call to
scm_sort_list_x, and gnetlist worked well.
The list passed to scm_sort_list_x is (1, 1).

Anyone knows what's the problem here?

Thanks,

Carlos

El sáb, 07-05-2005 a las 23:05 -0500, Neal Baer escribió:


I just compiled gEDA-2005080313, SuSE 9.2 yesterday.

I found what seems to be a bug with gnet-drc2.scm. Creating a simple schematic of 2 resistors, having the same reference (i.e. R1), same or different values, causes the DRC2 output as shown below.

I found the problem with a slotted part, thus each slot instance has the same reference designator. This stops the DRC2 testing to complete, which deems it useless in this scenario. I had to ensure that the reference numbers differ for the slotted parts to get DRC2 to complete its test.

Creating a netlist with the same reference numbers for slotted parts worked properly.

Any suggestions or workarounds?

Thanks,

Neal

DRC OUTPUT OF TEST SCHEMATIC WITH DUPLICATE REFERENCES



nbaer@linux:~/Projects/Terrigena/FILTER-DESIGN/FRONT-END-FILTER> gnetlist -g drc2 test.sch -o -
gEDA/gnetlist version 20050313
gEDA/gnetlist comes with ABSOLUTELY NO WARRANTY; see COPYING for more details.
This is free software, and you are welcome to redistribute it under certain
conditions; please see the COPYING file for more details.


Remember to check that your schematic has no errors using the drc2 backend.
You can do it running 'gnetlist -g drc2 your_schematic.sch -o drc_output.txt'
and seeing the contents of the file drc_output.txt.


Loading schematic [/home/nbaer/Projects/Terrigena/FILTER-DESIGN/FRONT-END-FILTER/test.sch]
Checking non-numbered parts...


Checking duplicated references...
ERROR: Duplicated reference R1.

Checking nets with only one connection...
ERROR: Net has only one connected pin: dgnd
ERROR: Net has only one connected pin: unnamed_net1

Checking type of pins connected to a net...

Checking unconnected pins...

Checking slots...

Checking duplicated slots...
ERROR: In procedure apply:
ERROR: Wrong type argument in position 1: #<variable 80661b8 binding: #<primitive-procedure <>>
nbaer@linux:~/Projects/Terrigena/FILTER-DESIGN/FRONT-END-FILTER>