[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: chassis ground - symbol errors, I wonder?
On Sat, 2009-10-03 at 01:10 +0200, Stefan Salewski wrote:
> On Fri, 2009-10-02 at 14:43 -0700, S. Aguinaga wrote:
> > Hello Fellows,
> > I've added a chassis ground and used the symbol: chassis.sym
>
> The symbol seems to be corrupt for gEDA 1.4.3:
>
> stefan@AMD64-X2 ~/gEDA/DAD $ cat /usr/share/gEDA/sym/IEC417/chassis.sym
> v 20031231 1
> P 200 300 200 100 1 0 0
> L 50 100 350 100 3 0 0 0 -1 -1
> L 350 100 300 0 3 0 0 0 -1 -1
> L 200 100 150 0 3 0 0 0 -1 -1
> L 50 100 0 0 3 0 0 0 -1 -1
>
> Try one of the other ground symbols shipped with geda or from
> www.gedasymbols.org. gnd-3.sym from my page there looks similar.
>
>
After closer inspection: I think the IEC417 symbols are for schematics
or block diagrams only, not for generating net lists. (Pins have no
pinnumbers, pinnames, ...). Use a GND symbol.