On Wednesday 30 April 2008 14:20:37 James Moody wrote:
> My circuit design spans 2 sheets. To carry the signal from one to the
> other I used the output and input flags, and added the attribute
> "netname=CH A_1" to the output on one page and the corresponding input
> on the other page.  I did the same with "CH A_2", "CH B_1" and "CH B_2".
> In the resulting netlist these nodes are unnamed, and the connection
> between sheets was not made.  I tried again after removing the space in
> the value; no difference.
>
Netname attributes should be attached to the net segments themselves. At the 
moment, the input/output flags are only used for heirachy.
Cheers,
                                 Peter
-- 
Peter Brett
Electronic Systems Engineer
Integral Informatics Ltd
Attachment:
signature.asc
Description: This is a digitally signed message part.
_______________________________________________ geda-user mailing list geda-user@xxxxxxxxxxxxxx http://www.seul.org/cgi-bin/mailman/listinfo/geda-user