Re: gEDA-user: OFF: triac



> MOC301x is ok for use in the US - in countries with 220 or 240VAC you 
> will need MOC302x optos.

Hadn't thought of that.  The app note has a schematic for using two in
series to switch 240v.

Also, I meant to say "alternistor" not alternac.  They have better
zero-crossing snubbing than a regular triac, but I'll probably switch
to a ZC opto for the next board (looking at the Toshiba SMT ones;