[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: Schematic import (was "why separate xgsch2pcb?")
On Sun, 2010-02-21 at 03:13 -0600, Vanessa Ezekowitz wrote:
> Since the Schematic Import was still giving me troubles, I've upgraded to GEDA 1.6.1 and pulled the latest PCB changes from GIT, uninstalled it, checked that there are no obvious references to PCB or GEDA anywhere under /usr/local (including that symlink that was previously needed), rebuilt and reinstalled.
>
> So now, the prefixes for PCB and GEDA are definitely the same. :-)
>
> As before, I've copied a known working schematic to ~/test.sch, and saved an empty board layout as ~/test.pcb, with "test" as the name on the layout.
>
> I then try to "Import Schematics", but it looks like things have taken a slight backward step: I am greeted with that single-line error message in the message log that cropped up before: "Can't add rat lines because no netlist is loaded". The only message on the controlling terminal is:
>
> Could not open actions file "/tmp/pcb.XXXCNCim/gnetlist_output"
>
> So as before I ran PCB via strace. The trace indicates that PCB is trying to find and run "defgnetlist" (and it checks in several places, including /usr/bin) with "test.sch" as one of the arguments. There are no executables anywhere in my $PATH that start with "def".
>
> Did I miss a step?
Looks like a mistake.. PCB has "defgnetlist" hard-coded rather than
"gnetlist".
Try with this environment variable set as a work-around for now:
PCB_GNETLIST="gnetlist"
(Use a full path if necessary).
Peter C