[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-user: SOT23



Below are my SOT23-5 and SOT23-6 elements that I
created using data from the Linear Technology S5 and
S6 
package specifications:

Element(0x0 "SOT-23-LTC-S5" "" "" -44 -121 0 100 0x0)
(
   Pad(-64 -37 -40 -37 24 "" "1" 0x0100)
   Pad(-64 0 -40 0 24 "" "2" 0x0100)
   Pad(-64 37 -40 37 24 "" "3" 0x0100)
   Pad(40 37 64 37 24 "" "4" 0x0100)
   Pad(40 -37 64 -37 24 "" "5" 0x0100)
   ElementLine(-18 -22 -18 -49 10)
   ElementLine(-18 -49 -5 -61 10)
   ElementLine(-5 -61 18 -61 10)
   ElementLine(18 -61 18 -22 10)
   ElementLine(-18 22 -18 61 10)
   ElementLine(-18 61 18 61 10)
   ElementLine(18 61 18 22 10)
   Mark(0 0)
)


Element(0x0 "SOT-23-LTC-S6" "" "" -44 -121 0 100 0x0)
(
   Pad(-64 -37 -40 -37 24 "" "1" 0x0100)
   Pad(-64 0 -40 0 24 "" "2" 0x0100)
   Pad(-64 37 -40 37 24 "" "3" 0x0100)
   Pad(40 37 64 37 24 "" "4" 0x0100)
   Pad(40 0 64 0 24 "" "5" 0x0100)
   Pad(40 -37 64 -37 24 "" "6" 0x0100)
   ElementLine(-18 -22 -18 -49 10)
   ElementLine(-18 -49 -5 -61 10)
   ElementLine(-5 -61 18 -61 10)
   ElementLine(18 -61 18 -22 10)
   ElementLine(-18 22 -18 61 10)
   ElementLine(-18 61 18 61 10)
   ElementLine(18 61 18 22 10)
   Mark(0 0)
)





--- Matt Ettus <boyscout@xxxxxxxxx> wrote:

> Is there a SOT23-5 footprint somewhere in PCB?  And
> does anyone have a
> mapping between SOTxx and SCxx numbers?
> 
> Thanks,
> Matt
> 



		
__________________________________ 
Do you Yahoo!? 
All your favorites on one personal page ? Try My Yahoo!
http://my.yahoo.com