Re: gEDA-user: GND vs. PGND



On Jan 9, 2007, at 10:38 AM, John Luciani wrote:

On 09 Jan 2007 18:13:35 +0100, David Kuehling <dvdkhlng@xxxxxx> wrote:
Hi,

I used both (analog) GND and PGND symbols in my layout. Now after
running gschem2pcb and loading the netlist file I see that those symbols
create two separated nets.


Still I want to connect GND and PGND somewhere in my layout without
making the DRC complain.  I tried to add a connection between GND and
PGND in my schematic, but that doesn't help.

If you attach two named nets to a component pin they will connect. See my simple example below.

A net with two names should throw a Big Fat DRC Error!