Re: gEDA-user: GND vs. PGND
>>>>> "John" == John Luciani <jluciani@xxxxxxxxx> writes:
> On 09 Jan 2007 18:13:35 +0100, David Kuehling <dvdkhlng@xxxxxx> wrote:
>> Hi,
>>
>> I used both (analog) GND and PGND symbols in my layout. Now after
>> running gschem2pcb and loading the netlist file I see that those
>> symbols create two separated nets.
>>
>> Still I want to connect GND and PGND somewhere in my layout without
>> making the DRC complain. I tried to add a connection between GND and
>> PGND in my schematic, but that doesn't help.
> If you attach two named nets to a component pin they will connect.
> See my simple example below.
Hi, thanks that works. gsch2pcbm issues a warning, but still better
than the alternative (using M-x query-replace :)
WARNING: Trying to rename something twice:
PGND and PGND
regards,
David
--
GnuPG public key: http://user.cs.tu-berlin.de/~dvdkhlng/dk.gpg
Fingerprint: B17A DC95 D293 657B 4205 D016 7DEF 5323 C174 7D40