On Wed, 2009-07-01 at 11:08 -0700, John P. Doty wrote:
>
> The question then is: what is a simple set of logical rules that should
> govern shorted nets?
Yesterday I have seen some more connected nets in my DSO schematics --
to ensure that it will work I have replaced them now with always the
same netname. This makes it more difficult to understand the schematics.
I think connection of nets would be fine, and if we connect net A with
net B the sum of both nets should be called something like A/B.
An other method may be a SPECIAL connection symbol in gschem for
connecting nets.
If this is not possible we really need a warning -- I have connected
nets multiple time in gschem schematics but never seen something like a
warning.
Best regards
Stefan Salewski