[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: BatchPCB
Jeff VR wrote:
> Hello,
> It seems the only room for error is in the batchpcb project submission
> page where it inquires about the software tool used for the design. I
> think this is for the drill file number format. I'm not really sure
> what I needed to put there so I tried a few different options. I opened
> the drill file and it looked like the format was "1.3 normal".
While I can't say for sure, I believe "1.3 normal" is what I have used
successfully in the past with BatchPCB.
>
> My design didn't have a back silk screen layer so I created a simple one
> by hand but that didn't get around the issue either.
>
> This is what the log file generates from batchpcb's drc checker for both
> the top and bottom layers:
> Beginning GCODE run
> Invalid DCODE 0
> GCode execution failed!
But... this isn't a complaint about the drill layer, is it? Isn't this
whining about top and bottom copper?
-dave