[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: How to fit REFDES on PCB with Hierarchy
Peter Clifton wrote:
> Another technique I tried (before the above), which the assembly house
> didn't like, was to outline the hierarchy blocks on the board. I added
> manual text to those blocks labelling the hierarchy block they belonged
> to. Within the block, the refdes text was stripped of its hierarchy
> prefixes.
This sounds so reasonable to me. But only if I think of humans doing the work.
I can see why a CM might want a unique refdes, or no refdes.The CM's robot might get lost
and think a refdes meant where it was -- untrue if it is repeated several times.
Or the CM's robot might have a vision system method of confirming placement that is confusable
by repeated refdes's.
I like Kai-Martin's compact form with "" as a hiearchy separator: 5R24. It's blown if
you have more than one sublevel from the top of hierarchy... or maybe not...
suppose top and 2 levels, then R's on three levels would be:
R1 R2 3R1 4R1 4R2 3S1R1 where S1 S2 ... designate 3rd level instances.
Its hard to pick a set of single letter names to use as instance names to use with a ""
separator, since so many are "used up" by first letters of component names: Cap Diode Fuse J(connector) L(inductor)
Q(transistor) Resistor Terminal U(IC) Varactor Xtal
John Griessen
--
Ecosensory Austin TX