Re: gEDA-user: gsch2pcb shorting circuits in netfile
On Sun, 2009-10-18 at 23:00 +0200, R. Bosch wrote:
> Hi all,
>
> I make a schematic, find no fault in the DRC (gnetlist -g drc2
> powerbox.sch).
> I generated the pcb files with "gsch2pcb Projectfile"
> I open the generated "powerbox_pcb.net" and spread out the footprints.
> I import the netlist and see "GND" has been created even though it
> doesn't exist in the schematic.
> I noticed it on conn2 from which conn2-1 and conn2-2 are both connected
> and the same goes for C5.
>
> Schematic:
> http://pastebin.ca/1627825
>
> Netlist:
> http://pastebin.ca/1627833
>
> LT1086-4:
> http://pastebin.ca/1627852
There is a GND net inside this symbol.
The other thought I had was.. what gEDA version are you using? Some of
the 1.5.x series had a nasty bug when creating net-lists with power
symbols. (Fixed by 1.5.3).
Best wishes.
Peter C.