Re: gEDA-user: geda 1.4.3, problems with BOM
On Tue, 22 Sep 2009 16:58:08 +0200, Stefan Salewski wrote:
> If I
> delete in this schematic the Power symbols 502 and 503 and replace them
> with a copy of 501 and renumber manually again to 502 and 503 all works
> fine
This description looks like an instance of the problem I tried to resolve
in my failed coding effort this summer. With composite components the
output of gnetlist depends on the order of symbols in the *.sch file. If
you delete power symbols and restore with a copy, you effectively move
the power symbol to the bottom of the file.
---<(kaimartin)>---
--
Kai-Martin Knaak tel: +49-511-762-2895
Universität Hannover, Inst. für Quantenoptik fax: +49-511-762-2211
Welfengarten 1, 30167 Hannover http://www.iqo.uni-hannover.de
GPG key: http://pgp.mit.edu:11371/pks/lookup?search=Knaak+kmk&op=get