[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: BOM of a hierarchal schematic (solved)
kai-martin knaak wrote:
> Looks like there is something foul with the configs at work...
Ok, I just spotted the cause: It was a matter of paths. gnetlist accepts and
finds a schematic with a valid path othere than the current working
directory. This processes just fine with a flat project. But gnetlist
assumes sub sheet symbols relative to the current working directory rather
than relative to the path of the main schematic. Consequently, the gnetlist
front end fails to find the bits and pieces of the hierarchy if the main
schematic was given with a path.
IMHO, gnetlist should extract the base path of the hierarchy from the
schematics argument rather than just assuming the current working directory.
Any objections?
---<)kaimartin(>---
--
Kai-Martin Knaak tel: +49-511-762-2895
Universität Hannover, Inst. für Quantenoptik fax: +49-511-762-2211
Welfengarten 1, 30167 Hannover http://www.iqo.uni-hannover.de
GPG key: http://pgp.mit.edu:11371/pks/lookup?search=Knaak+kmk&op=get
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user