[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: Matching footprints with symbols
On Sat, 2010-04-17 at 13:25 +0200, Stefan Salewski wrote:
> On Sat, 2010-04-17 at 13:10 +0200, Stefan Salewski wrote:
> > On Sat, 2010-04-17 at 12:37 +0200, Stefan Salewski wrote:
> >
> > >
> > > I think I have to rename all of them, including John Luciani's.
> > >
> > >
> >
> > You have components in your schematic named Rf and Cf without numbers.
> > These seems to have no connection in the netlist.
> > The missing number in refdes seems to be a problem.
> >
> >
>
> OK, seems to be all fixed now, see
>
> http://www.ssalewski.de/tmp/armin20100417.tar
>
>
> refdes without a digit at the end of the name seems to be indeed a big
> problem, I am not sure if this is stated at a prominent location in the
> gEDA/PCB documentation?
Specifically, it is the _lower case_ letter at the end which is ignored.
It was a (mis)feature designed to support "IC1a" "IC1b" as the same
part, "IC1" in the netlist.
I don't "think" upper case letters at the end of a refdes (without a
number) cause a problem.
--
Peter Clifton
Electrical Engineering Division,
Engineering Department,
University of Cambridge,
9, JJ Thomson Avenue,
Cambridge
CB3 0FA
Tel: +44 (0)7729 980173 - (No signal in the lab!)
Tel: +44 (0)1223 748328 - (Shared lab phone, ask for me)
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user