[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: slotting question
On Aug 23, 2011, at 8:45 PM, Dave McGuire wrote:
> On 08/22/2011 07:45 AM, Kovacs Levente wrote:
>>> I open up a new schematic, place two instances of 7404-1, edit the
>>> attributes of the second one, promote the "slot" attribute, edit the
>>> newly-accessible one, change it to "2", save it, save the sheet, exit
>>> gschem, restart, and load the sheet.
>>
>> I am guessing that you edit the symbol too. You don't have to. You just have
>> to save the sheet, not the symbol.
>
> Oh nono, I didn't do that...I was tired when I typed that. Where I said "save it, save the sheet" I just meant "save the sheet". I do not edit the symbols alone, other than double-clicking on them and promoting/modifying the slot attribute.
>
>> You should promote the slot attribute for both instances.
>
> Even though slot #1 defaults to 1?
>
> In any event, I've tried all combinations, and I still get the same behavior. This is with v1.6.2.20110115. This is repeatable here, using symbol 7404-1 from the default installed library.
>
> This seems like a pretty serious issue; can anyone shed a little light on it?
Absolutely mysterious. I've never seen behavior like this and I cannot reproduce it using your procedure.
John Doty Noqsi Aerospace, Ltd.
http://www.noqsi.com/
jpd@xxxxxxxxx
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user