[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: slotting question
Dave McGuire wrote:
> Here's the procedure:
>
> - start gschem (v1.6.2.20110115)
> - open library, select symbol "74-series logic/7404-1"
> - place two instances on sheet
<..snip..>
> - load file "test.sch"
> - note two inverter instances replaced with entire-package symbols
I still get the correct result.
A stab in the dark:
Maybe you have a copy of 7404-1.sym somewhere on your hardware that actually
is a 7404-3.sym in disguise. This disguised symbol file may be found first,
on start-up of gschem. You can test this hypothesis by not setting the slotting
at all and just save to text.sch . In addition you can use the "locate"
command to locate all symbol files called "7404-1.sym" on your hard disk.
HTH,
---<)kaimartin(>---
--
Kai-Martin Knaak
Email: kmk@xxxxxxxxxxxxxxx
http://pool.sks-keyservers.net:11371/pks/lookup?search=0x6C0B9F53
increasingly unhappy with moderation of geda-user
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user