[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-user: mosfet design help



carzrgr8@xxxxxxxxxxxxx wrote:
Dan, are you saying that the Cgd will allow the fast transient input to couple to the output?

Clamps may be able to reduce some of the slewing of your 50V signal that you'd end up with if you just used a divider. Maybe clamp each vgs to the opposite rail ... your fets will love getting switch with a 10 volt gate drive.


But wait! Doubting you'll have a super square 500kc PA, the clamps will cause distortion ... since they'd change the waveform you're trying to accurately monitor. Maybe the clamps are not such a good idea?

Thinking about it, though, any logic between your PA and the sensing circuit will cause distortion ... I don't know if you can tolerate it or not. Maybe you can get the op amp to flip your signal, if that has to happen.

pt