Re: gEDA-user: Re: question about autonumber in gschem HEAD
Hi Levente,
On Saturday 30 December 2006 18:19, Levente Kovacs wrote:
> Thank you very much for your answer!
>
> > Is this a question or a bug report? I'm not sure about it.
>
> This is a question about do I do something wrong, or gschem! :-)
gschem.
> > It should behave the following way:
> >
> > refdes=* searches for all text element that matches it:
> > -->refdes=C
> > -->refdes=CONN
> > -->refdes=R
> >
> > Then it renumbers each refdes with it's own numbers. If you have 5
> > capacitors and 5 connectors you should get:
> > C1-5 and CONN1-5
>
> I made further investigation on the problem. If there is a C? to be
> autonumbered before the CONN?, everything is numbered as C?. If the
> CONN? appears before C? Then everything works just fine.
I've found the bug and fixed it in cvs.
Thanks for your help.
Regards
Werner