[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-user: could not connect nets gschem/gsch2pcb/pcb



Klaus Rudolph <lts-rudolph@xxxxxx> wrote:
> Hi all,
> 
> I have a terrible problem which I could not solve :-(
> 
> I have a set of circuits drawn with gschem.
> I use gsch2pcb to make the netlist and use it in pcb
> 
> I allways get the following message:
> WARNING: Trying to rename something twice:
>        PLUS5V and PLUS5V
> are both a src and dest name
> This warning is okay if you have multiple levels of hierarchy!
> 
> As result my net PLUS5V is NOT connected to +5V and I could not route 
> the circuit in pcb :-(
> 
> Any hint to find the problem?

I guess you have one net with two names. Or you have one net with two same
power symbol attached to it.

> If needed, I could send you my working directory as a tgz as pm, I don't 
> want polute the list here :-)

Could you upload somewhere, and send the link?
 
> Thanks!
> Klaus

You are welcome.


-- 
Levente
http://web.interware.hu/lekovacs



_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user