Re: gEDA-user: Was there a major change to how power nets are handled in netlists?
On Mon, Feb 16, 2009 at 6:05 PM, Ales Hvezda <ahvezda@xxxxxxxxxxxxxx> wrote:
> Hi Matt,
>
>>In many of my schematics, I would have multiple power symbols, and
>>when I wanted them to be the same, I just connected them. However,
>>that no longer works! The netlister is making them separate nets.
>
> I cannot seem to reproduce this in a simple schematic. Could
> you do me a favor and take a look at the below schematic, netlist it with
> your gnetlist (on your machine), and let me know if:
>
> 1) it matches what you are doing in your large schematic
Only partially. I am using multiple sheets, and have many different
power connectors. I have tried to reproduce it with a smaller
schematic and was unsuccessful.
> 2) it netlists correctly or incorrectly for you.
Your example netlists correctly.
> I might not have interpreted your schematics correctly and maybe I am
> missing something subtle.
Did you see the same problem? The netlist I sent in the tarball shows
the problem. If you rerun the netlister, do you get the same output
as the netlist I sent you? If so, you have reproduced the problem :)
I will try making a smaller test case again, but haven't had luck so
far. I would feel better if I knew that you saw the problem in the
netlist I sent.
Thanks,
Matt