[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
gEDA-user: Re: gschem, gnetlist, hierarchy
- To: geda-user@seul.org
- Subject: gEDA-user: Re: gschem, gnetlist, hierarchy
- From: John Griessen <john_g@cibolo.com>
- Date: Thu, 29 Jan 2004 12:53:00 -0600
- Delivered-to: archiver@seul.org
- Delivered-to: geda-user-outgoing@seul.org
- Delivered-to: geda-user@seul.org
- Delivery-date: Thu, 29 Jan 2004 13:53:44 -0500
- In-reply-to: <20040129034816.0E59E33CF3@moria.seul.org>
- Organization: Cibolo Design
- References: <20040129034816.0E59E33CF3@moria.seul.org>
- Reply-to: geda-user@seul.org
- Sender: owner-geda-user@seul.org
Is this last part what is causing my gnetlists to include the page connector
as a part on the net it connects? Maybe if I put pinlabel=CLK2 and refdes=CLK2
and pinnumber=1 I will get a netlist with no mention of the page connector as desired?
John G
On Wed, 2004-01-28 at 21:48, Ales Hvezda wrote:
> for gnetlist, you also need the pinlabel= attribute on all pins.
> Then in the lower schematics, make the refdes of the connector symbols
> in-1.sym and out-1.sym (both the same really, just look different) the
> same as the appropriate pinlabel.
>
> The gTAG example has a working (as far as hierarchy is concerned)
> example. Also keep in mind that the generated netlist from gnetlist are
> completely flat.
>
> -Ales