[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

gEDA-user: Re: gschem, gnetlist, hierarchy



Is this last part what is causing my gnetlists to include the page connector 
as a part on the net it connects?   Maybe if I put  pinlabel=CLK2 and refdes=CLK2 
and  pinnumber=1  I will get a netlist with no mention of the page connector as desired?

John G



On Wed, 2004-01-28 at 21:48, Ales Hvezda wrote:
>  for gnetlist, you also need the pinlabel= attribute on all pins.
> Then in the lower schematics, make the refdes of the connector symbols
> in-1.sym and out-1.sym (both the same really, just look different) the
> same as the appropriate pinlabel.
> 
> 	The gTAG example has a working (as far as hierarchy is concerned)
> example.  Also keep in mind that the generated netlist from gnetlist are 
> completely flat.
> 
> 								-Ales