[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
gEDA-user: random observations
In no particular order. All observations pertain to the latest
version in fink (20061020).
+ Assume the symbol is not embedded in a schematic. If one edits an
element (text line, attribute whatever) in the symbol (either in a
text editor or using gschem), the next time the schematic is loaded,
only visible elements get updated. If you make all of the hidden
attributes visible, select a component and use ep (Update Component),
the attribute still doesn't update.
+ After gschm2pcb runs, it gives a list of "Next steps." Step 1 says
"From within PCB, select `File->disperse all elements.' " Actually,
"disperse all elements is in the Select menu.
+ Step 3 is "From within PCB, enter :ExecuteFile(boardname.cmd) to
propagate the pin mames of all footprints to the layout." It wasn't
obvious that you need to choose Window->Command Entry from the main
PCB menu. Also, the colon in front of :ExecuteFile causes the
command to fail (the terminal shows a log message, "unknown action
`:ExecuteFile"). Removing the colon does the trick.
+ It would be nice if the PCB Command Entry dialog's command-entry
drop-down listbox retained any previously-entered commands.
+ If you give a pin a pinlabel that includes parentheses (or perhaps
simply has a close parenthesis as the last character), for example,
VOut (tab), the ExecuteFile(boardname.cmd) complains with "unknown
action `)'"
+ gsch2pcb handles netnames with \_ \_ delimiters that indicate
active-low signals and has no trouble creating a netlist with these
characters included. Importing that netlist into pcb is fine, too.
However, if you save the pcb file, close pcb, then re-open the pcb
file in pcb, you get a syntax error in the pcb file at the first
instance of \_.
+ Having zoom in and zoom out as part of the history is driving me
bonkers. According to the archives, this is a religious issue.
Perhaps a way to toggle this would appease all gods?
+ Is there any way to have the net name appear on the pads and pins
in pcb?
+ Ratsnest rubberbanding seems to turn off for no reason.
-a
_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user