[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]
Re: gEDA-user: gschem/gnetlist question
Hi Zoran,
the DRC checker is telling you the net is not driven. This means that
only input or unknown pins are connected to that net, and that net will
be theoretically floating.
The reason is that the pintype attribute is missing in the symbols. The
pintype attribute tells the DRC the type of each pin (passive, input,
output, open collector, ...etc).
If you want to fix this, you have to edit the symbols you are using and
set the pintype correctly. For R's, C's, and L's it should be
"pas" (passive), for example. I'm not so sure about the voltage
generator.... maybe one pin should be "out" (output) and the other
"pwr" (power)?
There are some symbols with missing pintype attributes. They have to be
fixed.
Regards,
Carlos
El mar, 07-06-2005 a las 21:08 -0400, Zoran Spasojevic escribió:
> I am trying to learn how to use gschem and gnetlist but I can not get
> them to work even for a simple
> RLC circuit. Running
> gnetlist -g drc rlc.sch -o rlc.txt
> on the schematics rlc.sch gives the following output
>
> Probably parenthesis mismatch in
> /usr/local/geda/geda-install/share/gEDA/scheme/gnet-drc.scm
> Most recently read form: (define drc:attriblist (#@drc:parseconfig
> (#@open-input-file attribs)))
> ERROR: Unbound variable: drc
>
> Then when I run
> gnetlist -g drc2 rlc.sch -o rlc.txt
> I get
>
> Loading schematic [rlc.sch]
> ERROR: DRC errors found. See output file.
>
> Both drc and drc2 are in the man file for gnetlist.
> I included the output file in the attachment (rlc.txt). Perhaps someone
> can decipher it for me, to whom I will be grateful.
> I can not quite understand which attributes to specify for various
> components to get my schematics to work.
> Does anyone have an example of a simple RLC circuit that works? Or even
> better, can someone point the mistakes
> in the rlc.sch which I include in the attachment?
> Thanks in advance,
> Zoran
> plain text document adjunto (rlc.sch)
> v 20050313 1
> C 21300 65500 1 0 0 resistor-1.sym
> {
> T 21500 65800 5 10 1 1 0 0 1
> refdes=R1
> T 21600 65300 5 10 1 1 0 0 1
> value=17
> }
> C 23000 65600 1 270 0 inductor-1.sym
> {
> T 23300 65300 5 10 1 1 0 0 1
> refdes=L1
> T 23300 65000 5 10 1 1 0 0 1
> value=10uH
> }
> C 22800 64700 1 90 0 capacitor-1.sym
> {
> T 22300 65300 5 10 1 1 180 0 1
> refdes=C1
> T 22100 64900 5 10 1 1 0 0 1
> value=5nF
> }
> N 22200 65600 23600 65600 4
> N 21300 65600 21000 65600 4
> N 21000 64700 23600 64700 4
> C 20800 65600 1 270 0 voltage-3.sym
> {
> T 20500 65200 5 10 1 1 0 0 1
> refdes=V1
> T 20500 64900 5 10 1 1 0 0 1
> value=6V
> }
> plain text document adjunto (rlc.txt)
> Checking non-numbered parts...
>
> Checking duplicated references...
>
> Checking nets with only one connection...
>
> Checking type of pins connected to a net...
> ERROR: unknown: V1:2 C1:1 L1:2 connected to unknown: V1:2 C1:1 L1:2
> ERROR: Net unnamed_net3 is not driven.
> ERROR: unknown: V1:1 R1:1 connected to unknown: V1:1 R1:1
> ERROR: Net unnamed_net2 is not driven.
> ERROR: unknown: C1:2 L1:1 R1:2 connected to unknown: C1:2 L1:1 R1:2
> ERROR: Net unnamed_net1 is not driven.
>
> Checking unconnected pins...
>
> Checking slots...
>
> Checking duplicated slots...
>
> Checking unused slots...
>
> No warnings found.
> Found 6 errors.
--
Carlos Nieves Ónega <cnieves@xxxxxxxxxx>