On Wed, 10 May 2006 17:09:50 +0200 Stefan Dröge <gecko4ever@xxxxxx> wrote: > > I don't know much about control engineering, but in the text was also a > paragraph about PID. > But they said that this would require at least 3 parameters, and would > be too complex, and that adapting a PID-controller to the oven would > require founded awareness in controling engineering. It's mot so hard to implement. PID is now implemented in the reflow oven. ATmega8 is powerfull!!! C is cool! I just need some tuning on the protocol, and it'll be ready to publish. Levente -- http://web.interware.hu/lekovacs