[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-user: refdes and footprint not automatic from sym to sch



v 20050313 1
B 200 500 1200 1200 3 0 0 0 -1 -1 0 -1 -1 -1 -1 -1
{
T 200 1900 5 10 1 1 0 0 1
refdes=U?
T 200 1700 5 10 1 0 0 0 1
footprint=SO8W
}
The attributes are attached to the Box. But you need toplevel
attributes.

Yeah, it looks like Frank is trying to attach attributes to a box, which is a graphic object, not a component.

Frank, try reading these materials:

GEDA symbol creation guide:
http://geda.seul.org/wiki/geda:scg

GEDA gschem usage FAQ (contains lots of symbol info):
http://geda.seul.org/wiki/geda:faq-gschem#gschem_symbols

Stuart


_______________________________________________ geda-user mailing list geda-user@xxxxxxxxxxxxxx http://www.seul.org/cgi-bin/mailman/listinfo/geda-user