[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-user: DRC vs shorted nets?



OK shooting from the hip...


A pin or pad is definently connected to a net. Copper between pins/pads is less definite. How about a hot/cold system. Show copper changing from one net to the next based upon distance to the nearest pin/pad.



Just a wild assed non thought through idea....


Steve M.




Bob Paddock wrote:


Their location changed in such a way that the connectivity was changed. In
your sourceforge example, it placed a track right across the two pads of
C101. This is a nice solid short, not a tenuous one, thus there is no DRC,
only a short.

Ok, but it would be nice if something gave the location of the short. Change color, or X/Y points.

What defines "tenuous" distances? Zero is apparently not a tenuous distance.
How do the tenuous distances relate to the "DRC Minimium..." under the size menu? A distance of one gets a warning but zero does not?