[Author Prev][Author Next][Thread Prev][Thread Next][Author Index][Thread Index]

Re: gEDA-user: Error message when creating a SUBCKT



About the unused slots, it doesn't seems to be the problem.

When I add the 2 unused slots to my schematics and link theirs input pins to ground and output pin to NC symbol, drc2 removes the warning but the spice-sdb give me more "Invalid wanted_pin passed to get-nets [unknown]"

I've already use slots in another circuit without any problem.

Ludovic

On Sat, Aug 16, 2008 at 4:51 PM, Peter Clifton <pcjc2@xxxxxxxxx> wrote:
On Sat, 2008-08-16 at 09:26 -0400, John Doty wrote:
> On Aug 16, 2008, at 2:55 AM, Ludovic SMADJA wrote:
>
> > WARNING: Unused slot 3 of uref U2
> > WARNING: Unused slot 4 of uref U2
>
> I believe that unused slots are poison to the way spice-sdb works.
> For a slotted component, it expects that the model will implement all
> slots. Since pins are positional in SPICE netlists, it needs to list
> every pin on the component.

Perhaps for the spice backend, but IIRC, spice-sdb renames each slot, so
U2 becomes.

U2.1
U2.2
U2.3
U2.4

e.g. 4 components instantiated. I might be wrong in the fine-print though.

--
Peter Clifton

Electrical Engineering Division,
Engineering Department,
University of Cambridge,
9, JJ Thomson Avenue,
Cambridge
CB3 0FA

Tel: +44 (0)7729 980173 - (No signal in the lab!)



_______________________________________________



--
Ludovic SMADJA

_______________________________________________
geda-user mailing list
geda-user@xxxxxxxxxxxxxx
http://www.seul.org/cgi-bin/mailman/listinfo/geda-user